www.old.international-agrophysics.org / zeszyty


International Agrophysics
wydawca:Instytut Agrofizyki
im. B. Dobrzańskiego
PAN
w Lublinie
ISSN: 0236-8722


vol. 22, nr. 3 (2008)

poprzedni artykuł wróć do listy artykułów następny artykuł
Air cleaning in livestock buildings by applying the granular filtration layer
(pobierz wersję PDF)
R. Myczko , T. Kołodziejczyk
Department of Measurements and Ergonomics, Institute for Building Mechanization and Electrification of Agriculture in Warsaw, Poznań Branch, Biskupińska 67, 60-463 Poznań, Poland

vol. 22 (2008), nr. 3, pp. 245-248
streszczenie The assumptions and results of laboratory research on efficiency of ammonia removal from air by use of the cassette filter in the mechanical ventilation system were presented. A filtration layer consisted of polypropylene (PP) granulate of 5 mm grain diameter, enhanced during production process with NanoSilver concentrated preparation in concentration of 2 000 silver p.p.m. (nanoAg). Reduction factors came to: 45.1 and 51.4 at 16 l min-1 flow rate and 53.2 and 58.9% at 8 l min-1 flow rate for 0.5 and 1 l of granulate content in the layer respectively.
słowa kluczowe ammonia, emission, emission reduction, granular filter